集成聚合物样品制备系统

Polymer sample preparation PSL-Rheotek


ISP-1 Sample Preparation, supplied complete with precision balance, syringe Pump and voice promting software.
FAST – samples can be prepared in under 75 seconds.
Sample details are automatically transferred to the RPV-1.
Uses weight to weight data rather than weight to volume data to calculate concentration – avoids errors due to temperature/density.
Built-in safety checks.
Automatic ASH & MOISTURE corrections to concentration.
Uses AUDIO prompts to talk the operator through the essential preparation steps.
Pre-programmed methods make preparation simple and straightforward.
– Simple & Safe to use
– Improves accuracy
– Saves operator time
– Reduces exposure to hazardous chemicals
– Standard model suitable for most polymer applications
– Balance: 4 decimal place
– Interface: RS232C
– iSP-1 synge pump, 25ml
– Interface: RS232C
FULLY AUTOMATED SAMPLE PREPARATION SYSTEM to make accurate polymer concentrations
– W/W%
– W/V%
– Density
– Ash %
– Moisture %
Complete with…
BALANCE & PUMP
[uses PC on RPV-1]
Test Methods
ASTM D789, ISO 307, ASTM D4603, ASTM 2857, ASTM D1795, SCAN CM15:99, TAPPI T230-OM94, ASTM D1243, USP<911> Viscosity, ISO1628
The software is updated regularly – taking into account new methods or customer specific requests. Therefore if your method is not mentioned in the above list then please contact us.
Advantages
Simple & Safe to use
Improves accuracy
Saves operator time
Reduces exposure to hazardous chemicals
Ensures compliance with test methods
Description
Simple Operation
Operator selects one of the pre-programmed methods, types in the sample ID & presses the “Prepare Solution” button. The iSP-1 then takes over and asks the operator for the vial. The iSP-1 uses a series of audio prompts to instruct the operator how to prepare the sample. Safety checks ensure that the vial is placed on the balance. ISP-1 then asks for the sample. The operator adds sample until the iSP-1 prompts them to stop adding sample. Finally the iSP-1 calculates the correct amount of solvent and dispenses it into the vial.
Safety
Various safety checks throughout the process ensure the operators safety and prevent solvent being dispensed incorrectly.
Automatic Calculations, Results Database & LIMS
Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.
Materials of construction & design
The iSP-1 is supplied with a high quality MT balance. The iSP-1 pump is supplied with a tough chemical resistant coating. The pump can be disassembled for easy maintenance.
Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.
Typical Applications
– Pulp, Paper & Microcrystalline Cellulose, according to ASTM D1795 and SCAN CM15:98, TAPPI T230-OM94
– Nylon according to ASTM D789 [HIGH CONCENTRATION]
– Nylon according to ISO307[LOW CONCENTRATION]
PET according to ASTM D4603
PET in OCP [Orthochlorophenol]
PET in Phenol/Dichlorobenzene
特性粘度计,请联系15821107090, 专业工程师为您提供解决方案

Related posts